Direct Selection
PrismaTM QMS 200 F with Faraday detector
PrismaTMQMS 200 F1, 1-100 amu
QMS 200 F1, PrismaTM, 1-100 amu, Faraday, Tungsten, F200 °C , 0°
QMS 200 F1, PrismaTM 1-100 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F1, PrismaTM, 1-100 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F1, PrismaTM, 1-100 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F1, PrismaTM, 1-100 amu, Faraday, tungsten, F200 °C , 0°
PrismaTM QMS 200 F2, 1-200 amu
QMS 200 F2, PrismaTM, 1-200 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F2, PrismaTM, 1-200 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F2, PrismaTM, 1-200 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F2, PrismaTM, 1-200 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F2, PrismaTM, 1-200 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F2, PrismaTM, 1-200 amu, Faraday, tungsten, F200 °C , 0°
PrismaTM QMS 200 F3, 1-300 amu
QMS 200 F3, PrismaTM, 1-300 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F3, PrismaTM, 1-300 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F3, PrismaTM, 1-300 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F3, PrismaTM, 1-300 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F3, PrismaTM, 1-300 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F3, PrismaTM, 1-300 amu, Faraday, tungsten, F200 °C , 0°
QMS 200 F3, PrismaTM, 1-300 amu, Faraday, tungsten, F200 °C , 0°
PrismaPlusTM QMG 220 F with Faraday detector
PrismaPlusTM QMG 220 F1, 1-100 amu
QMG 220 F1, PrismaPlusTM, 1-100 amu, open ion source, W, 200 °C, 0°
QMG 220 F1, PrismaPlusTM, 1-100 amu, open ion source, W, 200 °C, 0°, IO 220 module
QMG 220 F1, PrismaPlusTM, 1-100 amu, open ion source, W, 200 °C, 90°
QMG 220 F1, PrismaPlusTM, 1-100 amu, open ion source, W, 200 °C,90°, IO 220 module
QMG 220 F1, PrismaPlusTM, 1-100 amu, open ion source, Y, 200 °C, 0°, IO 220 module
QMG 220 F1, PrismaPlusTM, 1-100 amu, open ion source, Y, 200 °C, 0°
PrismaPlusTM QMG 220 F2, 1- 200 amu
QMG 220 F2, PrismaPlusTM, 1-200 amu, open ion source, W, 200°C, 0°, IO 220 module
QMG 220 F2, PrismaPlusTM, 1-200 amu, open ion source, Y, 200°C, 0°, IO 220 module
QMG 220 F2, PrismaPlusTM, 1-200 amu, open ion source, W, 200°C, 0°
PrismaPlusTM QMG 220 F3, 1-300 amu
QMG 220 F3, PrismaPlusTM, 1-300 amu, open ion source, W, 200°C, 0°, IO 220 module
QMG 220 F3, PrismaPlus TM, 1-300 amu, open ion source, Y, 200°C, 0°, IO 220 module
Residual gas analysis in high vacuum
Toolbar :
The various versions of our compact mass spectrometers that incorporate Faraday detectors are outstandingly suited for qualitative analysis in the pressure range between 10-7 and 10-3. These instruments are characterized by their very good linearity and sensitivity.
Applications
- Residual gas analysis
- Leak detection under vacuum
- Qualitative analysis
- Vacuum furnaces
- Accelerators
Customer value
- Modular design affords the matching solution for many applications
- Interchangeability of analyzers and electronics
- Simple operation thanks to intuitive software
- Reliable identification of unknown gases
- High sensitivity thanks to field axis technology
- Low background thanks to biased ion source
- Multiple interfaces (AI, AO, DI, DO)
Favorites
To use this feature,
please sign on to the system (Login).
Compare Products
There are no products selected for comparison.